Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13637202

- Product Categories
- Friendly Links
Information Name: | UNT 4000 glycated hemoglobin analyzer Shanghai glycosylated hemoglobin analyzer |
Published: | 2015-01-03 |
Validity: | 30 |
Specifications: | No |
Quantity: | 1000000.00 |
Price Description: | |
Detailed Product Description: | Shenzhen glycated hemoglobin analyzer wholesale UNT 4000 glycated hemoglobin analyzer uses the most advanced diagnostic technology (the gold standard), to fill the gaps; easy to operate, just one minute to detect a full quantitative results; samples with less, 5ul peripheral blood / whole blood; [Testing Method] prior to the detection of all detection reagents should be balanced to room temperature. a) collecting a whole blood sample 5μL to R1 tube, mixed well, reacted at least 2 minutes, no more than 3 minutes. b) After a whole blood sample and R1 completion of the reaction, the tube again shaken to mix the components. Open the cell mixture 25μL draw, and added to the chromatographic reactor. Note Do not touch the chromatographic process is the membrane, do not let the samples have bubbles. c) When the step 2 mixture is completely absorbed chromatography device, again taken on 25μL R2 reagent dripping chromatography, the reaction of about 10 seconds. [Note] 1. For in vitro diagnostic use. 2, kit components from different batches can not be mixed. 3, R1 and R2 reagent reagent may be irritating, be careful not to use the process of direct contact with the skin. 4, R1 reagents and chromatography is for single use only. 5, after each pipetting steps to replace the tip. Interpretation of results] [Testing blood products and blood hemoglobin in red blood cells are bound to glycated hemoglobin, glucose and the formation of hemoglobin binding glycated hemoglobin is an irreversible reaction, and is proportional to blood glucose concentration, and maintained for 120 days, it can be observed 120 days before the blood glucose concentration. Glycosylated hemoglobin test can usually reflect glycemic control in patients with 8-12 weeks of near. [Note] 1. For in vitro diagnostic use. 2, kit components from different batches can not be mixed. 3, R1 and R2 reagent reagent may be irritating, be careful not to use the process of direct contact with the skin. 4, R1 reagents and chromatography is for single use only. 5, after each pipetting steps to replace the tip. Leonid gifted Biotechnology Co., Ltd., Guangdong Shenzhen glycated hemoglobin analyzer ___ Wholesale |
Admin>>>
You are the 13416 visitor
Copyright © GuangDong ICP No. 10089450, Biotechnology Co., Ltd., Guangdong gifted Ned All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 13416 visitor
Copyright © GuangDong ICP No. 10089450, Biotechnology Co., Ltd., Guangdong gifted Ned All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility